538 research outputs found

    Retention of basic laparoscopic skills after a structured training program

    Get PDF
    The purpose of this study was to test the retention of basic laparoscopic skills on a box trainer 1 year after a short training program. For a prior study, eight medical students without prior experience (novices) underwent baseline testing, followed by five weekly training sessions and a final test. During each of seven sessions, they performed five tasks on an inanimate box trainer. Scores were calculated by adding up the time to completion of the task with penalty points, consequently rewarding speed and precision. The sum score was the sum of the five scores. One year later, seven of them underwent retention testing for the current study. The final test results were compared with retention test results as a measure of durability of acquired skills. Novices’ scores did not worsen significantly for four out of five tasks (i.e., placing a pipe cleaner p = 0.46, placing beads p = 0.24, cutting a circle p = 0.31, and knot tying p = 0.13). However, deterioration was observed in the performance on stretching a rubber band (p < 0.05), as well as in the sum score (p < 0.05). Nevertheless, all retention scores remained better than the baseline results. In conclusion, basic laparoscopic skills acquired during a short training program merely sustain over time. However, ongoing practice is advisable, especially to preserve tissue-handling skills, since these may be the first to deteriorate

    A Plasma Survey Using 38 PfEMP1 Domains Reveals Frequent Recognition of the Plasmodium falciparum Antigen VAR2CSA among Young Tanzanian Children

    Get PDF
    PfEMP1 proteins comprise a family of variant antigens that appear on the surface of P. falciparum-infected erythrocytes and bind to multiple host receptors. Using a mammalian expression system and BioPlex technology, we developed an array of 24 protein constructs representing 38 PfEMP1 domains for high throughput analyses of receptor binding as well as total and functional antibody responses. We analyzed the reactivity of 561 plasma samples from 378 young Tanzanian children followed up to maximum 192 weeks of life in a longitudinal birth cohort. Surprisingly, reactivity to the DBL5 domain of VAR2CSA, a pregnancy malaria vaccine candidate, was most common, and the prevalence of reactivity was stable throughout early childhood. Reactivity to all other PfEMP1 constructs increased with age. Antibodies to the DBL2βC2PF11_0521 domain, measured as plasma reactivity or plasma inhibition of ICAM1 binding, predicted reduced risk of hospitalization for severe or moderately severe malaria. These data suggest a role for VAR2CSA in childhood malaria and implicate DBL2βC2PF11_0521 in protective immunity

    The use of curved vs. straight instruments in single port access surgery, on standardized box trainer tasks

    Get PDF
    BACKGROUND: Single-port access (SPA) surgery is a novel surgical technique to create nearly "scarless" surgery. SPA surgery appears to be safe and feasible, but the exposure and handling of tissue may not be optimal. Therefore, the performance of SPA surgery with different instruments used and conventional laparoscopy is compared. METHODS: Fifteen participants (>50 laparoscopic procedures) performed three basic tasks (translocation, clip & cut, and tissue dissection, based on the fundamentals of laparoscopic surgery) in the box trainer in laparoscopy and SPA settings with both (conventional) crossed and curved instruments. All participants completed a questionnaire, which asked their opinion on the use of instruments and preference. RESULTS: Translocation was performed significantly faster in both laparoscopy and SPA crossed than SPA curved (means, 130.3 and 137.7 vs. 170.7 sec; p < 0.001 and p = 0.005). The errors also were less in laparoscopy and SPA crossed (means, 0.9 and 1.2 vs. 1.6), but not significant. The time to complete the dissection was almost equal between laparoscopy and SPA curved settings, but took longer for SPA crossed, although not significantly (148.1 and 150.8 vs. 179.5 sec). The errors only differed significantly between laparoscopy and SPA crossed (means, 0.5 vs. 1.27; p = 0.044). Fourteen participants still favored conventional laparoscopy and one SPA curved. They also thought SPA curved was better than crossed (means, 3.6 vs. 2.47; p = 0.003) and that exposure is superior in curved (means, 3.4 vs. 2.27; p = 0.002). CONCLUSIONS: Although conventional laparoscopy may appear most effective for proper dissection and exposure of tissue, single-port access surgery shows potential. Especially in the tissue dissection task, there is no significant difference in time or errors between conventional laparoscopy and SPA surgery, using specially designed curved instruments. Although the participants favor conventional laparoscopy, this could evolve to a more accepting mind when SPA surgery becomes more available and used in the clinical setting

    Suturing training in Augmented Reality: gaining proficiency in suturing skills faster

    Get PDF
    Background: Providing informative feedback and setting goals tends to motivate trainees to practice more extensively. Augmented Reality simulators retain the benefit of realistic haptic feedback and additionally generate objective assessment and informative feedback during the training. This study researched the performance curve of the adapted suturing module on the ProMIS Augmented Reality simulator. Methods: Eighteen novice participants were pretrained on the MIST-VR to become acquainted with laparoscopy. Subsequently, they practiced 16 knots on the suturing module, of which the assessment scores were recorded to evaluate the gain in laparoscopic suturing skills. The scoring of the assessment method was calculated from the “time spent in the correct area” during the knot tying and the quality of the knot. Both the baseline knot and the knot at the top of the performance curve were assessed by two independent objective observers, by means of a standardized evaluation form, to objectify the gain in suturing skills. Results: There was a statistically significant difference between the scores of the second knot (mean 72.59, standard deviation (SD) 16.28) and the top of the performance curve (mean 95.82, SD 3.05; p < 0.001, paired t-test). The scoring of the objective observers also differed significantly (mean 11.83 and 22.11, respectively; SD 3.37 and 3.89, respectively; p < 0.001) (interobserver reliability Cronbach’s alpha = 0.96). The median amount of repetitions to reach the top of the performance curve was eight, which also showed significant differences between both the assessment score (mean 88.14, SD 13.53, p < 0.001) and scoring of the objective observers of the second knot (mean 20.51, SD 4.14; p < 0.001). Conclusions: This adapted suturing module on the ProMIS Augmented Reality laparoscopic simulator is a potent tool for gaining laparoscopic suturing skills.Industrial DesignIndustrial Design Engineerin

    Construct and face validity of SINERGIA laparoscopic virtual reality simulator

    Get PDF
    Purpose Laparoscopic techniques have nowadays become a gold standard in many surgical procedures, but they imply a more difficult learning skills process. Simulators have a fundamental role in the formative stage of new surgeons. This paper presents the construct and face validity of SINERGIA laparoscopic virtual reality simulator in order to decide whether it can be considered as an assessment tool. Methods Twenty people participated in this study, 14 were novices and 6 were experts. Five tasks of SINERGIA were included in the study: coordination, navigation, navigation and touch, precise grasping and coordinate traction. For each one of these tasks, a certain number of metrics are automatically recorded. All subjects accomplished each task only once and filled in two questionnaires. A statistical analysis was made and results from both groups were compared with the Mann–Whitney U-test, considering significant differences when P ≤ 0.05. Internal consistency of the system has been analyzed with the Cronbach’s alpha test. Results Novices and experts positively rated SINERGIA characteristics. At least one of the evaluated metrics of each exercise presented significant differences between both groups. Nevertheless, all metrics under study gave a better punctuation to the executions accomplished by experts (lower time, higher efficiency, fewer errors. . .) than to those made by novices. Conclusion SINERGIA laparoscopic virtual reality simulator is able to discriminate subjects according to their level of experience in laparoscopic surgery; therefore, it can be used within a training program as an assessment too

    Monitoring one-electron photo-oxidation of guanine in DNA crystals using ultrafast infrared spectroscopy

    Get PDF
    To understand the molecular origins of diseases caused by ultraviolet and visible light, and also to develop photodynamic therapy, it is important to resolve the mechanism of photoinduced DNA damage. Damage to DNA bound to a photosensitizer molecule frequently proceeds by one-electron photo-oxidation of guanine, but the precise dynamics of this process are sensitive to the location and the orientation of the photosensitizer, which are very difficult to define in solution. To overcome this, ultrafast time-resolved infrared (TRIR) spectroscopy was performed on photoexcited ruthenium polypyridyl–DNA crystals, the atomic structure of which was determined by X-ray crystallography. By combining the X-ray and TRIR data we are able to define both the geometry of the reaction site and the rates of individual steps in a reversible photoinduced electron-transfer process. This allows us to propose an individual guanine as the reaction site and, intriguingly, reveals that the dynamics in the crystal state are quite similar to those observed in the solvent medium

    Laparoscopic Video Analysis for Training and Image Guided Surgery

    Get PDF
    Automatic analysis of Minimally Invasive Surgical video has the potential to drive new solutions for alleviating needs of safe and reproducible training programs, objective and transparent evaluation systems and navigation tools to assist surgeons and improve patient safety. Surgical video is an always available source of information, which can be used without any additional intrusive hardware in the operating room. This paper is focused on surgical video analysis methods and techniques. It describes authors' contributions in two key aspects, the 3D reconstruction of the surgical field and the segmentation and tracking of tools and organs based on laparoscopic video images. Results are given to illustrate the potential of this field of research, like the calculi of the 3D position and orientation of a tool from its 2D image, or the translation of a preoperative resection plan into a hepatectomy surgical procedure using the shading information of the image. Research efforts are required to further develop these technologies in order to harness all the valuable information available in any video-based surgery

    High versus standard doses interferon-alpha in the treatment of naïve chronic hepatitis C patients in Taiwan: a 10-year cohort study

    Get PDF
    BACKGROUND: Interferon-alpha monotherapy is effective in less than one-third patients with chronic hepatitis C. The dose-effect, tolerability and durability of interferon-alpha treatment and its long-term effect on the prevention of cirrhosis and hepatocellular carcinoma in naïve Taiwanese patients with chronic hepatitis C have not been well investigated. We conducted the present cohort study treated with high and standard interferon-alpha to illustrate the issues. METHODS: We performed a long-term virologic and histological follow-up of 214 chronic hepatitis C patients treated with interferon-alpha, 3 million units (3-MU, n = 80) or 6-MU (n = 134) thrice weekly for 24 weeks, in Taiwan between 1992 and 2001. RESULTS: There was no difference in the incidence of discontinuation between 3-MU and 6-MU groups (4/80, 5.0% versus 10/134. 7.5%). The 6-MU group had similar incidence of adverse events with the 3-MU group, except that 6-MU group had significantly higher incidence of psychological manifestations, mainly presented as irritability. The rates of sustained virological response (SVR) were significantly higher in 6-MU regimen (37.1%) than in 3-MU regimen (23.7%, p < 0.05) in per protocol analysis. Based on multivariate analysis, baseline viral load was strongly associated with SVR, followed by hepatitis C virus genotype, interferon-alpha regimen, and liver fibrosis. A histological improvement in necroinflammatory activity, but not in fibrosis was observed in the follow-up biopsy performed 0.5–5.5 years (mean: 1.9 years, n = 51) after end-of-treatment. Among patients without SVR, there was more activity improvement in 6-MU group. The durability of SVR was 100% (18/18) and 97.8% (45/46) for 3-MU and 6-MU group, respectively, in a mean follow-up period of 6.81 years (5.25–9.18 years). For 163 baseline non-cirrhotic patients, 9 of 84 (10.7%) non-responders and 3 of 79 (3.8%) sustained responders progressed to cirrhosis during a mean follow-up period of 5.52 and 5.74 years, respectively (p = 0.067, Kaplan-Meier survival analysis, log-rank test). For all 200 patients, hepatocellular carcinoma was detected in 12 of 113 (10.6%) non-responders and one of 87 (1.1%) sustained responders during a mean follow-up period of 5.67 and 5.73 years, respectively (p < 0.01, Kaplan-Meier survival analysis, log-rank test). CONCLUSION: We confirm the dose effect of interferon-alpha in chronic hepatitis C. Six-MU regimen had better efficacy than 3-MU regimen in virologic and histological responses. Both regimens had good tolerability and durability in Taiwan. Sustained response could reduce the incidence of cirrhotic change and hepatocarcinogenesis
    corecore